External risk intelligence

ASSA ABLOY Seawing SC-1000 WebConfig Command Injection

CVE advisorySeverity: CRITICAL (CVSS 9.4)

CVE-2026-97180

The affected product is a web-based configuration interface for an access control appliance. Such management interfaces are commonly deployed as network-accessible services to facilitate remote administration and device configuration, increasing the likelihood of exposure in operational environments.

OS Command Injection

Halo Surface Signal: 4 out of 5 — likely to be public-facing.

External exposure likelihood

Horizon Alert

Summary of the vulnerability and why it matters

The ASSA ABLOY Seawing SC-1000 WebConfig presents a critical vulnerability, allowing remote command injection through unvalidated HTTP requests. This could enable a privileged attacker to execute arbitrary commands as the root user, impacting the operating system.

  • Attackers can inject commands via web requests.
  • This could allow unauthorized system control.
  • Confirm relevance and assess potential exposure.

Attack Path

How an attacker could exploit the issue

A privileged attacker can exploit this vulnerability by sending a crafted HTTP request to the vulnerable web configuration interface. This request manipulates the 'server' parameter without proper input sanitization, allowing the attacker to inject malicious commands. If successful, these commands can be executed with root privileges on the underlying operating system.

  • Requires privileged access.
  • Inject commands via HTTP request.
  • Arbitrary command execution as root.

Live Threat

Current exploitation, exposure, and threat context

A privileged attacker could execute arbitrary commands as the root user on the operating system of an ASSA ABLOY Seawing SC-1000 WebConfig appliance. This is possible when the appliance is accessible via HTTP and the attacker can inject shell metacharacters into the server parameter due to insufficient input sanitization.

  • Root operating system access.
  • Via unauthenticated HTTP requests.
  • Complete system compromise.

Operational Fix

Recommended remediation, mitigation, and detection steps

The ASSA ABLOY Seawing SC-1000 WebConfig's remote command injection vulnerability likely impacts teams responsible for operational technology (OT) security, access control systems, and potentially network infrastructure. The first practical step is to inventory all SC-1000 devices, confirm their network exposure, and identify the specific system owners or the vendor responsible for their management and maintenance. This will allow for a risk-based remediation plan, which may involve vendor coordination or applying provided fixes during planned maintenance windows.

  • Own the inventory and exposure confirmation.
  • Verify network reachability and business criticality.
  • Plan remediation with vendor coordination.

Supplementary metadata

Validate whether this threat affects your internet-facing exposure.

Halo Threat Intelligence helps prioritize remediation with Halo Surface Signal and H/A/L/O context. Start exposure validation with a free external attack surface trial.

Frequently asked questions

What is the ASSA ABLOY Seawing SC-1000 WebConfig?

The Seawing SC-1000 is an access control appliance used for physical security management. Its WebConfig component is a web-based interface that allows administrators to configure device settings, manage user access, and oversee network-connected entry points remotely.

How does CVE-2026-97180 enable command injection?

This vulnerability stems from a weakness known as OS Command Injection (CWE-78). It occurs because the software fails to sanitize user-provided data. By inserting shell metacharacters into the 'server' parameter of an HTTP request, an attacker can trick the system into executing their own arbitrary commands directly on the underlying operating system with root-level authority.

Do I need to worry about any HTTP request triggering this?

No. This bug is not triggered by just any HTTP request. The system specifically requires the attacker to hold privileged access to the interface to interact with the vulnerable 'server' parameter. If an attacker cannot authenticate or lacks the necessary permissions to reach and modify that specific setting, the command injection path remains closed.

Why does Halo Surface Signal categorize this as external?

Halo Surface Signal labels this as external because the product is a management interface, which is frequently configured to be network-accessible to support remote administration. When these interfaces are reachable from broader network segments or the internet, the attack surface expands, making it possible for remote actors to reach the vulnerable parameters.

Is there a first step for managing this threat?

Start by identifying every SC-1000 unit within your environment. Once you have a complete inventory, verify whether these devices are accessible over your network and determine who is responsible for their maintenance. This information allows you to coordinate with the vendor to apply the necessary software update, version 1.5.14, during your next planned maintenance window.

References